GE® Extra-Large 5.7 Cu. Ft. Capacity Frontload Electric Dryer
Dimensions and Installation Information (in inches) | ||||||||
Exhaust Options: Electric—4-way via rear, right, left | ||||||||
and bottom. | ||||||||
Circuit Requirements: Electric—An individual, | B | |||||||
properly-grounded branch circuit, protected by a 30- | ||||||||
amp circuit breaker or a time-delay fuse, is required. | ||||||||
Electric Dryer Rating: | ||||||||
120/240V, 3-wire, 5600W, 24A | Electric | |||||||
120/208V, 3-wire, 4400W, 22A | Connection | |||||||
Note: Dryer wall outlet must be located within 36” | ||||||||
of service cord entry and accessible when dryer is | ||||||||
mounted in position. | H | |||||||
Installation Information: For complete information, | I | |||||||
see installation instructions packed with your dryer. | ||||||||
3/16' | ||||||||
Gas Pipe Connection | ||||||||
REAR VIEW |
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000.
Ge Venue 50 User Manual Pdf 2 10
Door Open | F |
90° | Optional |
Vent Knockout | |
C | |
SIDE VIEW | G |
Listed by
Underwriters
Laboratories
DSXH43EFWW
GE® Extra-Large 5.7 Cu. Ft. Capacity Frontload Electric Dryer
Dimensions and Installation Information (in inches)
Special Installation Requirements Undercounter Installation
Accessory mounting kits are required for undercounter installation. To order, call 1-800-848-7722.
Ge Venue 50 User Manual Pdf File
Stacked Installation: Brackets for stacking dryer over washer are included with the dryer.
Alcove or Closet Installation:If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back. The dryer MUST be exhausted to the outdoors. Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0' either side, 3' front and rear Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52'. Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally
distributed. The closet should be vented to the outdoors to prevent gas pocketing in case of a gas leak in the supply line. No other fuel-burning appliance shall be installed in the same closet with the dryer.
Bathroom or Bedroom Installation: The dryer must be exhausted to the outdoors. The installation must conform with the local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.
Minimum Clearances other than Alcove or Closet Installations:
Minimum clearances to combustible surfaces: 0' both sides, 3' rear
Free-Standing Installation
36'
25-3/4'
53-1/2'
Stacked Installation
70-5/8'
For answers to your Monogram,® GE Profile™ or | 25-3/4' |
26-3/4' | |
GE® appliance questions, visit our website at | |
geappliances.com or call GE Answer Center® | |
service, 800.626.2000. |
e | |||
Wid | |||
x3/4' | |||
High | Sides | ||
3/4' | |||
All | |||
on | |||
Lip |
14'
29' | 56'-60' |
Max. |
Undercounter Installation
User Manual
Countertop
Ge Venue 50 User Manual Pdf User
Washer
Top Sheet
Instruction Manual
Specification Revised 12/09 | 360426 |